Power Switching Transfer Generator Switch Dual Millisecond Automatic 80A


Power Switching Transfer Generator Switch Dual Millisecond Automatic 80A

  • Marchio: Unbranded
Venduto da:

Power Switching Transfer Generator Switch Dual Millisecond Automatic 80A

  • Marchio: Unbranded

Attualmente non disponibile

Politica di reso a 14 giorni

Venduto da:

Attualmente non disponibile

Politica di reso a 14 giorni

Metodi di pagamento:

Descrizione

Power Switching Transfer Generator Switch Dual Millisecond Automatic 80A

Feature: 1. MILLISECOND SWITCHING: When there is an abnormality in the normal power supply, the automatic transfer switch will switch in millisecond to the backup power supply to ensure the continuity of the power supply. 2. AUTO MANUAL MODE: This dual power transfer switch can be operated automatically or manually, which is isolated anti interference, reliable and stable. 3. STANDARD RAIL INSTALLATION: The power transfer switch adopts standard 35mm rail installation method, specially designed for PZ30 distribution box. 4. EXCELLENT MATERIAL: The changeover switch adopts flame retardant PC shell, with good insulation and heat resistance. Silver contact is anti aging, with excellent conductivity. 5. WIDELY USED: The power transfer switch can be used in various occasion where continuous power outages are not allowed, such as home, shopping mall, factory. Specification: Item Type: Dual Power Automatic Transfer Switch Material: PC, Silver Model: NLQ3 125 2P Rated Current le: 80A Insulation Voltage Ui: AC690V Rated Voltage Ue: AC110V Frequency: 50/60Hz Rated Control Voltage US: 110VAC 85% Us to 110% Us Grade: PC Grade Specification: 2P Service Life: Electrical: 2000 Times, Mechanical: 5000 Times Rated Short Circuit Current: 50kA Fuse: RT16 00 63A Rated Impulse Withstand Voltage: 8kV Auxiliary Circuit: Two Relays, Each With Two Sets Contact Capacity: AC110V 50HZ le=5y Touch Time: <50ms Operation Conversion Time: <50ms Return Time: <50ms Closing Time: <50ms Package List: 1 x Dual Power Automatic Transfer Switch Note: 1. The maximum ambient temperature shall not exceed 40℃, the minimum temperature shall not be less than ‑5℃, and the average temperature within 24 hours shall not exceed 35℃. 2. The altitude of the installation site should not exceed 2000m. 3. When the maximum temperature reaches 40℃, the relative humidity of the installation site should not exceed 50%. When the temperature is at the lowest temperature of ‑5℃ and the relative humidity is high, for example, at a temperature of 25℃, the relative humidity is 90%. Due to temperature changes, special measures should be taken to deal with occasional condensation on the surface of the product. How To Use 1. Before installation, please check the integrity of the ATS, use the operating handle to turn it on or off, check the flexibility of the transmission device, and detect the generation and disconnection conditions of normal and backup power loads at each stage. 2. Wiring and use according to wiring diagram.
  • ID Fruugo: 492674192-1016578898

Consegna

Spedito entro 3 giorni

Spedizione da Cina.

Resi

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli.

Visualizza la politica di reso completa