10a Lcd Rail Digital Display Thermostat Temperature Humidity Controller With Sensor Dual Channel Relay Module

CHF 30.95
+ CHF 11.49 Spedizione

10a Lcd Rail Digital Display Thermostat Temperature Humidity Controller With Sensor Dual Channel Relay Module

  • Marchio: Unbranded
Venduto da:

10a Lcd Rail Digital Display Thermostat Temperature Humidity Controller With Sensor Dual Channel Relay Module

  • Marchio: Unbranded

CHF 30.95

Economizzare CHF 18.00 (36%)

Prezzo di vendita consigliato

CHF 48.95
Disponibile
+ CHF 11.49 Spedizione

Politica di reso a 14 giorni

Venduto da:

CHF 30.95

Economizzare CHF 18.00 (36%)

Prezzo di vendita consigliato

CHF 48.95
Disponibile
+ CHF 11.49 Spedizione

Politica di reso a 14 giorni

Metodi di pagamento:

Descrizione

10a Lcd Rail Digital Display Thermostat Temperature Humidity Controller With Sensor Dual Channel Relay Module

The functions of the product are mainly classified into two categories: temperature function and humidity function; The temperature function is as follows: 1. Automatic working mode identification: The system automatically recognizes the working mode according to the start temperature/stop temperature; Start temperature > stop temperature, cooling mode 'C'; starting temperature < stop temperature, heating mode 'H'; 2. Cooling mode: When the detected temperature starting temperature, the relay is activated, the red light is on, and the refrigeration equipment starts to work; When the temperature of detection the stop temperature, the relay is off, the red light is off, and the refrigeration equipment stops working; 3. Heating mode: When the detected temperature the starting temperature, the relay is turned on, the red light is on, and the heating equipment starts to work; When the temperature detection stop temperature, the relay is closed, the red light is off, and the heating equipment stops working 4. OFE(-10.0 ~ 10.0) temperature correction function: The system works for a long time and deviations may occur. Through this function correction, the actual temperature = measured temperature + value calibration; How to set start/stop temperature: 1. On the running interface, press and hold "TM+" key for more than 3 seconds to enter the start temperature setting interface. The test can modify the parameters via the TM+ TM- key. When finished changing settings, wait 6 seconds to automatically exit and save; 2. In the running interface, press and hold "TM-" key for more than 3 seconds to enter the shutdown temperature setting interface. The test can modify the parameters via the TM+ TM- key. When finished changing settings, wait for 6 seconds to automatically exit and save; Humidity functions are as follows: 1. Automatic working mode identification: The system automatically recognizes the working mode according to the start humidity/stop temperature; Start humidity > stop humidity, dehumidification mode d; start humidity < stop humidity, humidification mode E; 2. Dehumidification mode: When the detected humidity start humidity, the relay is activated, the green light is on, and the dehumidification equipment starts to work; When the humidity detectedstop the humidity, the relay is off, the green light is off, and the dehumidification equipment stops working; 3. Humidification mode: When the detected humidity the starting humidity, the relay is activated, the green light is on, and the humidification device begins to work; When the humidity detected stops the humidity, the relay is turned off, the green light is off, and the humidification device stops working 4. RH humidity correction function (-10.0 ~ 10.0 ): The system works for a long time and there may be deviations. With this function correction, the actual humidity = measured humidity + calibration value; How to set start/stop humidity: 1. On the running interface, press and hold the "RH+" button for more than 3 seconds to enter the start humidity setting interface. The test can change the parameters by pressing the RH + RH- button. When the settings change is complete, wait 6 seconds to automatically exit and save; 2. On the running interface, press and hold "RH-" button for more than 3 seconds to enter the stop humidity setting interface. The test can change the parameters by pressing the RH + RH- button. When finished changing settings, wait 6 seconds to automatically exit and save
  • ID Fruugo: 260672669-570063672
  • EAN: 165930638942

Informazioni sulla sicurezza del prodotto

Si prega di consultare le informazioni sulla sicurezza del prodotto specifiche per questo prodotto descritte di seguito

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Etichette di sicurezza del prodotto

CE Mark
Avvertenze di sicurezza: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Ingredienti: Octinoxate 6.2%
Codice articolo del produttore: QD56001
Numero di modello: QD491782
Numero di serie: QD51954
Numero di lotto: QD692690

Consegne e Resi

Spedito entro 3 giorni

  • STANDARD: CHF 11.49 - Consegna tra mer 07 gennaio 2026–mar 13 gennaio 2026

Spedizione da Cina.

Facciamo del nostro meglio per assicurare che i prodotti che ordini vengano consegnati integralmente e secondo le tue indicazioni. Tuttavia, nel caso dovessi ricevere un ordine incompleto, oppure articoli differenti rispetto a quelli che hai ordinato, o se c'è qualche altro motivo per il quale non sei soddisfatto dell'ordine, puoi effettuare il reso dell'ordine, o qualsiasi prodotto incluso nell'ordine e ricevere un rimborso completo per gli articoli. Visualizza la politica di reso completa

Dettagli sulla conformità del prodotto

Si prega di consultare le informazioni di conformità specifiche per questo prodotto descritte di seguito.

Le seguenti informazioni sono fornite dal rivenditore terzo indipendente che vende questo prodotto.

Produttore:
Le seguenti informazioni sono i dati di contatto del produttore del prodotto rilevante venduto su Fruugo.

  • Chen Yuxin
  • Tielingweiyaoshangmaoyouxiangongsi
  • No. 84-10, South Section of Chaihe Street, Yinzhou District, Tieling City, Liaoning Province
  • Tieling City
  • China
  • 112000
  • zhoulu1913@outlook.com
  • 13534297882

Persona responsabile nell'UE:
Le seguenti informazioni sono informazioni dei contatto della persona responsabile nell'UE. La persona responsabile è l'operatore economico designato con sede nell'UE, responsabile degli obblighi di conformità relativi al prodotto in questione venduto nell'Unione Europea.

  • CREAMDEL SASU
  • CREAMDEL SASU
  • CHEZ DOMIDEAL, 11 AVENUE CARNOT, 25000
  • BESANCON
  • France
  • 25000
  • Stupidpuppyeu@outlook.com
  • 33751334518