Photoelectric Photocell Dusk to Dawn Button Flush Mount Photo Control Eye Switch
Feature
*NK101A type light controller for lamps, suitable for automatic switching control of street lamps, garden lamps, corridor lamps, door lamps and other lighting lamps
*This type of light controller can realize the control function of day and night according to the change of light intensity in nature
*The light controller is designed based on the micro-electric heating structure and includes an ambient temperature compensation mechanism, and its work is not affected by changes in ambient temperature
*The light control has a 20-120 second anti-interference delay hold function, which can avoid damaging switching operations on the controlled lamps
Specification
Model: NK-101A
Rated voltage: 120V
Voltage range: 105-130VAC
Rated frequency: 50/60Hz
Rated load: 1.5A
No-load power consumption: 1.2A Max
On/Off: 10-20LUX ON, 30-60LUX OFF
Anti-interference delay: 20-120s
Ambient temperature: (-40°C) (+70°C)
Relative humidity: 95%
Type: Line-Control
Dimensions: 35.20(L)×13.60(W)×20.50(H)mm
Probe size: 10 (diameter) × 17 (height)
Weight: 20grs
Lead length: 18AWG105℃ 180mm
Shell design: in line with the American National Standard ANSIC136.10 standard
Certification: UL & CUL (E494798)
Scope of use: road lighting, street and garden lighting, garden lighting, LED lighting, etc.
Use period: use 5000 times
Installation Notes
1. Cut off the power supply, remove the lamp cover or control box cover, and pass the light controller probe from the inside out of the reserved hole (diameter is slightly larger than 10mm) and screw on the plastic nut from the outside (if necessary, double nuts can be customized for both inside and outside. side) Connect the power supply and lamp circuit according to the diagram on the right.
2. Do not point the transparent casement of the probe towards the artificial light source or its opposite, otherwise the light control will make the controlled lamps cycle on and off at night.
3. When the power is turned on after the initial installation, it will immediately enter the normal working state. During the initial test during the day, the transparent casement of the probe may be covered with black tape or similar material, and the controlled luminaire should be lit. Do not cover with your fingers, as light leakage can still keep the light switch off.
Packing list:
1*Light control switch
NK101A type light controller for lamps, suitable for automatic switching control of street lamps, garden lamps, corridor lamps, door lamps and other lighting lamps
This type of light controller can realize the control function of day and night according to the change of light intensity in nature
The light controller is designed based on the micro-electric heating structure and includes an ambient temperature compensation mechanism, and its work is not affected by changes in ambient temperature
The light control has a 20-120 second anti-interference delay hold function, which can avoid damaging switching operations on the controlled lamps Specification Model: NK-101A Rated voltage: 120V Voltage range: 105-130VAC Rated frequency: 50/60Hz Rated load: 1.5A No-load power consumption: 1.2A Max On/Off: 10-20LUX ON, 30-60LUX OFF Anti-interference delay: 20-120s Ambient temperature: (-40°C) (+70°C) Relative humidity: 95% Type: Line-Control Dimensions: 35.20(L)×13.60(W)×20.50(H)mm Probe size: 10 (diameter) × 17 (height) Weight: 20grs Lead length: 18AWG105℃ 180mm Shell design: in line with the American National Standard ANSIC136.10 standard Certification: UL & CUL (E494798) Scope of use: road lighting, street and garden lighting, garden lighting, LED lighting, etc. Use period: use 5000 times Installation Notes 1. Cut off the power supply, remove the lamp cover or control box cover, and pass the light controller probe from the inside out of the reserved hole (diameter is slightly larger than 10mm) and screw on the plastic nut from the outside (if necessary, double nuts can be customized for both inside and outside. side) Connect the power supply and lamp circuit according to the diagram on the right. 2. Do not point the transparent casement of the probe towards the artificial light source or its opposite, otherwise the light control will make the controlled lamps cycle on and off at night. 3. When the power is turned on after the initial installation, it will immediately enter the normal working state. During the initial test during the day, the transparent casement of the probe may be covered with black tape or similar material, and the controlled luminaire should be lit. Do not cover with your fingers, as light leakage can still keep the light switch off. Packing list: 1
Light control switch
-
Identifiant Fruugo:
433728158-910456696
-
EAN:
9039326574958
Informations sur la sécurité des produits
Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.
Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.
Avertissements de sécurité:
WARNING: Opening and/or repairing your device may result in risk of electric shock, damage to the device, fire and personal injury, and other hazards. We recommend that you seek professional assistance for device repairs and exercise caution when repairing your device yourself.
Ingrédients:
Other
Livraison & retours
Expédition dans un délai de 3 jours
Expédition de Chine.
Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour