Parasitic Drain Tester for Automotive Battery Testing AH

13.95 CHF
+ 13.99 CHF Livraison

Parasitic Drain Tester for Automotive Battery Testing AH

  • Marque: Unbranded
Verkocht door:

Parasitic Drain Tester for Automotive Battery Testing AH

  • Marque: Unbranded

13.95 CHF

Économisez 10.00 CHF (41%)

Prix de vente recommandé

23.95 CHF
En stock
+ 13.99 CHF Livraison

Politique de retour sur 14 jours

Verkocht door:

13.95 CHF

Économisez 10.00 CHF (41%)

Prix de vente recommandé

23.95 CHF
En stock
+ 13.99 CHF Livraison

Politique de retour sur 14 jours

Modes de paiement:

Description

Parasitic Drain Tester for Automotive Battery Testing AH

Features: 1、Replaceable in-line fuses protect both the meter and tester in the event a high current source on the vehicle is left on. 2、The multimeter is bypassed with the switch during connection in case of a power surge. 3、The tester and meter can remain connected until other computer systems shut down, isolating the drain. 4、As a convenience, stacking banana connectors are used on the tester. Specification: Provides an easy method to connect a multimeter to the vehicle electrical system to diagnose hidden battery drain. Features: Replaceable in-line fuses protect both the meter and tester in the event a high current source on the vehicle is left on. The multimeter is bypassed with the switch during connection in case of a power surge. The tester and meter can remain connected until other computer systems shut down, isolating the drain. As a convenience, stacking banana connectors are used on the tester. Specifications: Material: Plastic Package Size: 20 * 14 * 3.5cm Package Weight: 150g Package List: 1 * Drain Tester Instructions: 1. Park and turn off the engine, open the hood, lock the door, and wait for the ECU to enter sleep. 2. Clamp the battery terminal (negative) with the spring clip, then use the fully wrapped battery clip to clamp the battery terminal clip (negative)/ground. 3. Flip the switch to the ON position (l/closed); Plug the 4mm banana plug (red) into the multimeter A/10/20A jack, and the 4mm banana plug (black) into the multimeter COM jack.Turn the dial of the multimeter to point to the A/10A/20A gear. 4. Loosen the battery terminal clip nut with M10 wrench, then disconnect the battery terminal clip from the battery terminal, which can be separated by cardboard or plastic sheet. 5. Turn the switch to OFF (O/Disconnect) to read the current value by multimeter. 6. If you need to change the range of the multimeter, you should turn the switch to ON (l/Closed), and then turn the multimeter dial. Select the appropriate range and re-plug to 4mm banana jack (red) [if necessary], and then turn the switch to OFF (ON/Disconnect). Notes: 1. Please turn off the engine and remove the key before testing the current leakage. Do not start the engine during the test to avoid burning the . 2. Current leakage testing needs to simulate the usual state when the car is power-off, please be sure to shut the door, pull out the key (can be locked), so that the car computer into a sleep state. 3. Different car computers enter the hibernation state at different times, so please be patient when measuring to determine whether current leakage is generated. 4. The computer standby current varies from car to car, but the ideal value should be between 20 mA and 60 mA. 5. It is recommended to use a 10A to replace the of the line tester to avoid burning the multimeter. Package List: 1 * Drain Tester Instructions: 1. Park and turn off the engine, open the hood, lock the door, and wait for the ECU to enter sleep. 2. Clamp the battery terminal (negative) with the spring clip, then use the fully wrapped battery clip to clamp the battery terminal clip (negative)/ground. 3. Flip the switch to the ON position (l/closed); Plug the 4mm banana plug (red) into the multimeter A/10/20A jack, and the 4mm banana plug (black) into the multimeter COM jack.Turn the dial of the multimeter to point to the A/10A/20A gear. 4. Loosen the battery terminal clip nut with M10 wrench, then disconnect the battery terminal clip from the battery terminal, which can be separated by cardboard or plastic sheet. 5. Turn the switch to OFF (O/Disconnect) to read the current value by multimeter. 6. If you need to change the range of the multimeter, you should turn the switch to ON (l/Closed), and then turn the multimeter dial. Select the appropriate range and re-plug to 4mm banana jack (red) [if necessary], and then turn the switch to OFF (ON/Disconnect). Notes: 1. Please turn off the engine and remove the key before testing the current leakage. Do not start the engine during the test to avoid burning the . 2. Current leakage testing needs to simulate the usual state when the car is power-off, please be sure to shut the door, pull out the key (can be locked), so that the car computer into a sleep state. 3. Different car computers enter the hibernation state at different times, so please be patient when measuring to determine whether current leakage is generated. 4. The computer standby current varies from car to car, but the ideal value should be between 20 mA and 60 mA. 5. It is recommended to use a 10A to replace the of the line tester to avoid burning the multimeter.
  • Identifiant Fruugo: 503293390-1031521128
  • EAN: 6254357698982

Informations sur la sécurité des produits

Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Étiquettes de sécurité des produits

CE Mark
Avertissements de sécurité: Do not let your children touch this product alone to avoid swallowing or other injuries

Livraison

Expédition dans un délai de 2 jours

  • STANDARD: 13.99 CHF - Livraison entre lun. 06 juillet 2026–lun. 13 juillet 2026

Expédition de Chine.

Retours

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles.

Voir l'intégralité de la politique de retour

Détails de conformité du produit

Veuillez consulter les informations de conformité spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Fabricant:
Les informations suivantes indiquent les coordonnées du fabricant du produit concerné vendu sur Fruugo.

  • Harbin Tandi E-commerce Co., Ltd.
  • Harbin Tandi E-commerce Co., Ltd.
  • No. 2, Floor 7, Unit 4, Building 3, Science and Technology Garden, 140 meters northwest of Taiyangsheng Collective Building, Songbei District, Harbin City
  • Heilongjiang Province
  • China
  • 150000
  • [email protected]
  • 18111812335

Personne responsable dans l'UE:
Les informations suivantes indiquent les coordonnées de la personne responsable dans l'UE. La personne responsable est l'opérateur économique désigné basé dans l'UE qui est responsable des obligations de conformité relatives au produit concerné vendu dans l'Union européenne.

  • EC REP SERVICES SL
  • EC REP SERVICES SL
  • Calle Gran Via 49, 7 Dch.
  • Madrid
  • Spain
  • 28013
  • [email protected]
  • 0034-682797075