Electronic Load 150W Constant Current Board Battery Discharge Capacity Tester Module

40.95 CHF
+ 2.49 CHF Livraison

Electronic Load 150W Constant Current Board Battery Discharge Capacity Tester Module

  • Marque: Unbranded
Verkocht door:

Electronic Load 150W Constant Current Board Battery Discharge Capacity Tester Module

  • Marque: Unbranded

40.95 CHF

Actuellement indisponible
+ 2.49 CHF Livraison
Verkocht door:

40.95 CHF

Actuellement indisponible
+ 2.49 CHF Livraison

Nous acceptons les modes de paiement suivants

Description

Feature 11602 LCD screen, display information comprehensively 2Configuration of 9cm CPU fan, very quiet 3With temperature display, supporting the discharge and voltage setting 4Test all kinds of power load or burin-in, can also test capacity of battery discharge 5Load maximum power 150W, maximum voltage 60V, maximum current 10ASpecification Description: This is an electronic load board of very high cost performance, adopting two completely independent 18 bit ADC chip, 15 PPM voltage benchmark, which allows a high accuracy. It is better than other electronic load with single chip built-in AD sampling digital tube display or battery capacity tester. Supporting user second correction of parameters, it is a best choice for DIY users. Features: 1602 LCD screen, display information comprehensively. Configuration of 9cm CPU fan, very quiet. With temperature display, supporting the discharge and voltage setting. Test all kinds of power load or burn-in, can also test capacity of battery discharge. Load maximum power 150W, maximum voltage 60V, maximum current 10A. Specifications: Voltage: DC 12V5% Load Type: Constant current Load Voltage: 0.5-60V Load Current: 0-10A Maximum Power: 150W Voltage Reading Precision: (0.1%+0.05%FS) Current Reading Precision: (0.2%+0.1%FS) Constant Current Accuracy: Current reading Precision + 1d Noise: 25dD(A) Weight: 341g(approx.) Instruction: Wiring Diagram of 2 Wires (Safe and convenient): Note: 2 wires must be respectively connected to A+ and A-. V+ is connected to A+, and V- is connected to A-. Wiring Diagram of 4 Wires: Note: 4 wires must be connected completely before use. 4 wires can offset voltage drop caused by electric wires under large current and ensures a more accurate voltage measurement. It is recommended if you are a professional. 4 wires must be all connected correctly before you power on the load. Wrong wiring is likely to cause damage, please make sure the wiring is correct! As you can see in the picture, there are thick wires and thin wires. The thick wires are for current, the thin wires are for measuring voltage, and of course you can use thick wires for all. Below is the operation interface. The operation is very simple and easy(when it displays "ON", it must be connected to load, otherwise it will beep and won't work) Bottom left screen corner will display information that automatic switching between power, AH, temperature, time, and can be set to always display certain one. "I": Setting load current "V": Setting discharge cut-off voltage. 1, the power adapter: DC 12V, load power and power supply should be 2 independent power. 2, Power on and screen shows "Welcome to use" which means equipment is normal 3, Press "set" to move the cursor, add and subtract operations according to the cursor position. When the cursor position is at "I" or "V", press "add" or "subtract" button to switch current and voltage setting. 4, Connect to power source that need to be tested, and make sure the wiring is correct. 5, Press "start" button to start/stop electronic load, and screen shows "ON" or "OF" 6, Press and hold "start" button for more than 1 second to reset AH and time, and power off the electronic load (if it was powered on) 7, The bottom left screen corner will display information that automatic switching by default every 2 seconds between power, AH, temperature, time. Press and hold "set" button, then press "add" button to switch, and the display information will not switch automatically. If you need the information to switch automatically again, press and hold "set" button, then press "subtract" button till bottom right screen corner shows "Auto". 8, Settings will be automatically saved after power failure. Electric loaf need to be manually started when power is back. 9, Continuous operation power of load is associated with operating temperature. When temperature is too high, operation power should be reduced. If the heat sink temperature reaches 87 , the load will automatically reduce power. When the core temperature reaches 91 , it will stop work, and need to be manually started after cooling. 10, Load current will be automatically adjusted according to the input voltage. For example, if set 10A, and the input voltage is 20V, then it automati
  • Identifiant Fruugo: 196667684-419360283
  • EAN: 4142380075646

Informations sur la sécurité des produits

Veuillez consulter les informations de sécurité du produit spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Étiquettes de sécurité des produits

CE Mark
Avertissements de sécurité: Please use and store the product correctly according to the instructions

Livraison & retours

Expédition dans un délai de -1 jours

  • STANDARD: 2.49 CHF - Livraison entre lun. 03 novembre 2025–ven. 07 novembre 2025

Expédition de Chine.

Nous mettons tout en œuvre pour que les produits que vous commandez vous soient livrés dans leur intégralité et selon vos indications. Néanmoins, si vous recevez une commande incomplète, des articles différents de ceux commandés ou si, pour toute autre raison, la commande ne vous satisfait pas, vous pouvez retourner la commande ou tout produit inclus dans celle-ci et recevoir un remboursement complet des articles. Voir l'intégralité de la politique de retour

Détails de conformité du produit

Veuillez consulter les informations de conformité spécifiques à ce produit décrites ci-dessous.

Les informations suivantes sont fournies par le détaillant tiers indépendant vendant ce produit.

Fabricant:
Les informations suivantes indiquent les coordonnées du fabricant du produit concerné vendu sur Fruugo.

  • Shenzhen Yangxi Trading Co., Ltd.
  • Shenzhen Yangxi Trading Co., Ltd.
  • No. 203, No. 3, Lane 3, Houshan West, Xiaxue Village, Xinxue Community, Bantian Street, Longgang
  • Shenzhen
  • CN
  • 518129
  • wqvkk3@163.com

Personne responsable dans l'UE:
Les informations suivantes indiquent les coordonnées de la personne responsable dans l'UE. La personne responsable est l'opérateur économique désigné basé dans l'UE qui est responsable des obligations de conformité relatives au produit concerné vendu dans l'Union européenne.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM. 1, PLANTA 1, DERECHA, OFICINA 3, Fuenlabrada, Madrid, 28947 Spain
  • Frankfurt am Main
  • ES
  • 28947
  • successservice2@hotmail.com
  • 34910602659